This Project reads out the sensor connected to the FINO2 Host PC (for the profiling lift). Currently there is only a WCS1800 sensor connected, which reads out the AC current flowing from the solid state relay to the AC/DC in the winch-side-box
You can not select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
 
 
FINO2_HostPC_2 4c2d9b5324 dfgydfg 1 month ago
code dfgydfg 1 month ago
data dfgydfg 1 month ago
.gitignore changes 1 month ago
readme.txt added readme.txt 2 months ago

readme.txt

This Project reads out the sensor connected to the FINO2 Host PC (for the profiling lift).
Currently there is only a WCS1800 sensor connected, which reads out the AC current flowing from the solid state relay
to the AC/DC in the winch-side-box

HOW IT WORKS:
-run the WCS1800_control.py file to start continous measurement
-the script reads out the runtime parameters from data/readout_timings.json
-the script saves all gathered date in daily telegrams and one "recent" telegram in the "output" folder

TODO:
-autostart this script
-automatically read out the generated data
-put data in database
-find method to "zero" the WCS1800 sensor when no current is flowing to the AC/DC